Rev. bras. ortop ; 56(2): 138-146, Apr.-June 2021. graf
Article in English | LILACS | ID: biblio-1251348

ABSTRACT

Abstract The increase in the number of revision total knee arthroplasty surgeries has been observed in recent years, worldwide, for several causes. In the United States, a 601% increase in the number of total knee arthroplasties, between 2005 and 2030, is estimated. Among the enormous challenges of this complex surgery, the adequate treatment of bone defects is essential to obtain satisfactory and lasting results. The adequate treatment of bone defects aims to build a stable and lasting support platform for the implantation of the definitive prosthetic components and, if possible, with the reconstruction of bone stock. Concomitantly, it allows the correct alignment of the prosthetic and limb components, as well as restoring the height of the joint interline and, thus, restoring the tension of soft parts and load distribution to the host bone, generating a joint reconstruction with good function, stable, and painless. There are several options for the management of these bone defects, among them: bone cement with or without reinforcement with screws, modular metallic augmentations, impacted bone graft, structural homologous graft and, more recently, metal metaphyseal cones, and metaphyseal sleeves. The objective of the present article was to gather classic information and innovations about the main aspects related to the treatment of bone defects during revision surgeries for total knee arthroplasty.


Resumo O aumento do número de cirurgias de revisão de artroplastia total do joelho tem sido observado nos últimos anos, em todo o mundo, por diversas causas. Nos Estados Unidos, é estimado um aumento de 601% no número de artroplastias totais do joelho entre 2005 e 2030. Dentre os enormes desafios dessa cirurgia complexa, o adequado tratamento dos defeitos ósseos é essencial para a obtenção de resultados satisfatórios e duradouros. O adequado tratamento dos defeitos ósseos objetiva construir uma plataforma de suporte estável e duradoura para a implantação dos componentes protéticos definitivos e, se possível, com recomposição do estoque ósseo. Concomitantemente, possibilita o correto alinhamento dos componentes protéticos e do membro, assim como permite restabelecer a altura da interlinha articular e, dessa forma, restaurar a tensão de partes moles e distribuição de carga ao osso hospedeiro, gerando uma reconstrução articular com boa função, estável e indolor. Diversas são as opções para manejo dessas falhas ósseas, entre elas: cimento ósseo com ou sem reforço com parafusos, aumentos metálicos modulares, enxerto ósseo impactado, enxerto estrutural homólogo e, mais recentemente, cones metafisários de metal trabecular e sleeve metafisário. O objetivo do presente artigo foi reunir informações clássicas e inovações dos principais aspectos relativos ao tratamento das falhas ósseas durante as cirurgias de revisão de artroplastia total do joelho.


Subject(s)
Bone and Bones/abnormalities , Bone Transplantation , Arthroplasty, Replacement, Knee
2.
São Paulo; s.n; 2015. 56 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-763789

ABSTRACT

O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes...


The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols...


Subject(s)
Immediate Dental Implant Loading/methods , Immediate Dental Implant Loading , Tomography, X-Ray Computed
3.
Rev. bras. ortop ; 49(4): 364-369, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-722695

ABSTRACT

Objective: this study aimed to evaluate the fixation of the trabecular metal wedge in patients undergoing revision of total hip arthroplasty. Methods: twenty-three cases with minimum grading of Paprosky II-B that were operated between July 2008 and February 2013 were evaluated. These cases were evaluated based on radiographs before the operation, immediately after the operation and later on after the operation. Loss of fixation was defined as a change in the abduction angle of the component greater than 10° or any mobilization greater than 6 mm. Results: it was found that there was 100% fixation of the acetabula after a mean of 29.5 months. One case underwent removal of the implanted components due to infection. Conclusions: there is still no consensus regarding the best option for reconstructing hips with bone loss. However, revision using a trabecular metal wedge has presented excellent short-and medium-term results. This qualifies it as an important tool for achieving a fixed and stable acetabular component...


Objetivo: avaliar a fixação das cunhas de metral trabeculado (CMT) em pacientes submetidos à revisão de artroplastia total de quadril. Métodos: foram avaliados 23 casos graduados no mínimo como II-B de Paprosky, operados entre julho de 2008 e fevereiro de 2013. Os casos foram avaliados com base nas radiografias pré e pós-operatórias imediatas e tardias. A perda da fixação foi definida como uma variação do ângulo de abdução do componente maior do que 10° ou qualquer mobilização maior do que 6 mm. Resultados: verificou-se 100% de fixação dos acetábulos após 29,5 meses em média. Um caso foi submetido à retirada dos componentes implantados por infecção. Conclusões: ainda não há consenso no que diz respeito à melhor opção de reconstrução do quadril com perda óssea, porém a revisão com CMT vem apresentando excelentes resultados em curto e médio prazo. Tal fato a qualifica como uma importante ferramenta na obtenção de um componente acetabular fixo e estável...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Prostheses and Implants
4.
Rev. bras. ortop ; 47(6): 714-718, 2012. tab
Article in Portuguese | LILACS | ID: lil-666214

ABSTRACT

OBJETIVO: Avaliar o valor da avaliação radiográfica pré-operatória nas revisões de artroplastias totais do joelho. MÉTODOS: Trinta e um joelhos operados no período de 2006 a 2008 em uma série consecutiva de casos de cirurgia de revisão de artroplastia total de joelho foram analisados retrospectivamente. CRITÉRIOS ANALISADOS: número de cunhas ou enxertos ósseos estruturados utilizados para preenchimento dos defeitos ósseos; localização das cunhas e enxertos ósseos utilizados e espessura média do polietileno utilizada. A classificação AORI era estabelecida previamente através de radiografias pré-operatórias segundo critérios preestabelecidos. Após a análise, os joelhos foram divididos em quatro grupos (I, IIA, IIB e III). RESULTADOS: O número médio de cunhas ou enxertos ósseos utilizados em cada joelho variou de maneira crescente entre os grupos (grupo I: 1,33; grupo IIA: 2; grupo IIB: 4,33; grupo III: 4,83) (P = 0,0012). As localizações mais comuns foram: medial na tíbia e posteromedial no fêmur. Não houve diferença estatisticamente significante na espessura do polietileno utilizado. CONCLUSÃO: A classificação AORI para defeitos ósseos no joelho baseada em radiografias pré-operatórias mostrou correlação crescente com a necessidade de utilização de cunhas e/ou enxertos estruturados na revisão de artroplastia total do joelho. Porém, até 46% dos joelhos dos grupos I e IIA apresentaram falhas ósseas de até 5mm não diagnosticadas através das radiografias pré-operatórias.


OBJECTIVE: To evaluate the value of preoperative radiographic evaluations for total knee arthroplasty (TKA) revision. METHODS: Thirty-one knees that were operated between 2006 and 2008, in a consecutive series of cases of TKA revision surgery were analyzed retrospectively. THE FOLLOWING CRITERIA WERE EVALUATED: number of wedges or structured bone grafts used for filling the bone defects; locations of the wedges and bone grafts used; and mean thickness of the polyethylene used. The AORI classification was previously established based on preoperative radiographs, using preestablished criteria. After the analysis, the knees were divided into four groups (I, IIA, IIB and III). RESULTS: The mean number of wedges or grafts used in each knee progressively increased among the groups (group I: 1.33; group IIA: 2; group IIB: 4.33; and group III: 4.83) (P = 0.0012). The commonest locations were medial in the tibia and posteromedial in the femur. There were no statistically significant differences in the thickness of the polyethylene used. CONCLUSION: The AORI classification for bone defects in the knee, based on preoperative radiographs, showed a correlation with increasing need to use wedges and/or structured grafts in TKA revisions. However, up to 46% of the knees in groups I and IIA presented bone defects of up to 5 mm that were not diagnosed by means of preoperative radiographs.


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Bone and Bones/injuries , Radiography/classification